Mechanical ventilation
or an open window.

In a closed bedroom of 28 m³ the carbon dioxide concentration reaches 3700 ppm by morning. In a bedroom of 92 m³ it reaches 1400 ppm. Same night, same people, same window tightness. The difference is the volume of air.

How much CO₂ builds up overnight

The model assumes a bedroom of a given area and clear height, two people, window and door closed, no mechanical ventilation. The full distribution, and what happens once a supply is switched on, is in the study of night, air and quiet; storey height as a reserve of air is counted in the study of building services:

BedroomVolumeCO₂ after eight hours
11 m² at 2.5 m clear height28 m³3700 ppm
13 m²38 m³2800 ppm
16 m²49 m³2270 ppm
21 m²64 m³1845 ppm
30 m²92 m³1400 ppm

At 30 m³ per hour per person the concentration settles at about 920 ppm regardless of room size.

Does it matter

It does, and it is measured. Danish studies at DTU compared sleep with the window closed and open: mean overnight concentration was 2585 ppm against 660 ppm, and better ventilation improved sleep efficiency and next-day test results (Strøm-Tejsen et al., 2016).

One detail matters more for design than the headline. Across twenty-nine bedrooms (Fan et al., 2022), sleep improved only with an open window. Opening the door to the corridor lowered CO₂ but did not improve sleep. A room does not exchange air with the rest of the house the way an open plan suggests.

Why an open window is not always enough

The WHO recommends below 30 dB in a bedroom at night. A tilted window cuts outside noise by about 15 dB (WHO, 1999), so it works only where the outside level is no more than about 45 dB.

Outside the windowOutside levelInside, window tilted
Quiet residential street40 dB25 dB, within guidance
Threshold45 dB30 dB, at the limit
Distributor road55 dB40 dB, too loud
Trunk road65 dB50 dB, too loud

The question to ask on site

Not whether to install heat recovery, but how many decibels there are here at night. That decides whether bedrooms can face the road, and it belongs to the massing stage, not the services stage.

In the Polish climate bedroom windows are shut at night from roughly October to April, seven months a year. Without mechanical ventilation, concentration in a bedroom below about 58 m³ exceeds 2000 ppm.

What follows from this

  • The volume of a bedroom is a health parameter. Floor area times clear height decides what you breathe towards morning.
  • Noise on the plot is measured before the bedroom is placed. Above 45 dB at night, a bedroom by a road needs mechanical ventilation, not thicker glass.
  • Heat-recovery ventilation in a premium house is not a comfort extra. It is the only solution to a problem that occurs every night for more than half the year.

Dates, limits and parameters reflect the law as it stood when the text was last updated. This is not legal advice, nor a design assessment of any particular plot. What you may build is decided by the local plan or the planning decision for your own plot. We are happy to read it.