Part 12 ·
Sixty-nine per cent of a day
happens inside the house.
A third of it in one room.
About sixty-nine per cent of a day is spent inside the house, and a third of the whole day asleep in one room of it. Whatever a house does to health, it does over that much time. This part is about which of those effects can be designed, and which only measured.
The twelfth and last part of the series on the plan study. A warning before the numbers: everything below comes from cohort studies, which show associations and not causes, and none of it is medical advice.
Where the day goes
Source: NHAPS, Klepeis et al., 2001, a time-use study of over nine thousand people in the United States. Of the sixty-nine per cent at home, roughly a third of the whole day is spent asleep, in one room.
That is the whole reason this part exists. A gym membership covers a few hours a week. A house covers the rest.
What comes out of the studies
Cohort studies on populations from several thousand to ninety thousand people. These are associations, not proof of cause. The bar shows the middle of the range where the source gives one. Sources: sauna and dementia Laukkanen et al., Age and Ageing 2017, sauna and death Laukkanen et al., JAMA Internal Medicine 2015, sleep Windred et al., Sleep 2024, cooking Chen et al., Public Health Nutrition 2012, bath Ukai et al., Heart 2020, strength training Momma et al., British Journal of Sports Medicine 2022, stairs Song et al., Atherosclerosis 2023, daylight Windred et al., PNAS 2024.
The two strongest results concern heat and sleep, and both depend on something a plan can influence: whether a sauna is within reach, and whether a bedroom is dark, quiet and ventilated.
Eight areas in which a house has something to say
| Area | What the architect controls |
|---|---|
| Sleep and daily rhythm | orientation of the bedroom, blackout, evening and night light, air and quiet in the bedroom |
| Light | the size and orientation of windows in the places where the day is spent: study, kitchen, dining room |
| Air | mechanical ventilation, a cooker hood ducted outside, an induction hob, radon protection |
| Sound | the position of the bedroom relative to the road and to the laundry, reverberation in the living area |
| Movement | stairs used every day, a gym of 6 to 10 m², the length of the circulation |
| Heat | a sauna close to a shower and somewhere to cool down, a bath in the main bathroom, protection against overheating in summer |
| Food and people | a kitchen open to the dining room, a table for six to eight, a pantry |
| Ageing | a room and a bathroom with a shower on the ground floor, space reserved for a lift shaft |
Eight areas from the part of the report devoted to a long healthy life, translated into design parameters.
How our houses compare
This is a profile of possibilities, not an assessment of the residents’ health. What counts is whether, and how often, someone uses a given element.
Eleven units have a sauna, and all of them are houses above roughly three hundred and eighty square metres. No development unit has one. This is the area where a smaller house can gain the most at the least cost, because a bath in the main bathroom gives the same stimulus as a sauna, only more cheaply.
Thirteen units have a gym, from ten to fifty square metres. For thirty to sixty minutes of strength training a week, the dose from the studies, six to ten square metres are enough, with a bar, a bench and dumbbells. A larger room holds cardio machines, but it does not move the health threshold any further.
One thing comes out the opposite way from what we expected: spread-out houses, with long circulation and the garage far from the kitchen, generate more steps. It is a rare case in which a less convenient layout can be healthier.
From research to a drawing
A list of factors changes nothing by itself. It starts to matter once each one has a parameter the architect controls, a target value from a standard or a study, a moment when the decision is taken and a way of checking it on a drawing. That is how the standard we use inside the studio came about.
| Element | What it means |
|---|---|
| Three levels | basic applies to every project, including developer work; extended to houses from about 250 m²; premium to large residences |
| Four stages | concept (massing, orientation, layout), building design (dimensions, envelope, stairs), detailed design (light, ventilation, acoustics), fit-out (shading, materials) |
| Eight areas | sleep, light and daily rhythm, air, sound, movement, heat, food and people, ageing |
| A checklist | each area ends with a list that can be worked through on the drawings, not in a finished house |
Most of the basic-level requirements are about where rooms sit relative to one another, not about extra square metres.
The most important consequence of that split is this: requirements from the concept stage cost nothing, and after the concept they cannot be recovered. You cannot later move the bathroom door into the bedroom. You cannot move a utility room away from a bedroom wall. You cannot turn a bedroom to face east.
What the standard asks for, in numbers
| Parameter | Target | Source |
|---|---|---|
| Light in a bedroom at night | up to 1 lx melanopic EDI | Brown et al., PLOS Biology 2022 |
| Light in the evening, three hours before sleep | up to 10 lx melanopic EDI at eye level | Brown et al., PLOS Biology 2022 |
| Light in the morning and during the day | from 250 lx melanopic EDI | Brown et al., PLOS Biology 2022 |
| Daylight in the living space | 300 lx over half the area, about a 2 per cent factor | EN 17037 |
| Noise in a bedroom at night | up to 30 dB(A), peaks up to 45 | WHO, Guidelines for community noise, 1999 |
| Road noise outside a bedroom window at night | up to 45 dB | WHO, Environmental noise guidelines, 2018 |
| Reverberation in the living space | 0.5–0.8 s | our own measurement |
| Carbon dioxide in a bedroom | 1000–1200 ppm at a supply of about 30 m³ per person per hour | EN 16798-1, Strøm-Tejsen et al., Indoor Air 2016 |
| Radon | below 300 Bq/m³ | Polish Atomic Law, WHO, Handbook on indoor radon, 2009 |
| Temperature in winter | at least 18 °C, 18–21 for sleeping | WHO, Housing and health guidelines, 2018 |
| Sauna | two to three times a week, so it has to be within reach | Laukkanen et al., JAMA Internal Medicine 2015 |
Melanopic EDI is light weighted by the sensitivity of the body clock rather than the eye. At the same number of lux, cold light counts for more than warm.
Living on the ground floor at seventy-five
Fourteen of our twenty units can be used without going upstairs.
Which brings the only conclusion worth drawing from this part. The expensive version of all of it is a conversion at seventy-five. The cheap version is a drawing at forty.
What costs nothing
| Decision | Cost | When it is taken |
|---|---|---|
| Bedrooms east, living space south and east | PLN 0 | concept |
| Bathroom with its door from the bedroom, utility room off the bedroom wall | PLN 0, it is a question of layout | concept |
| Space reserved for a lift shaft | about 2 m² per storey | concept |
| Separate circuits for evening and night lighting | a few points at PLN 160–200 each | detailed design |
| Blackout blinds | PLN 50–300 per window | fit-out |
| Extracting hood, induction hob, radon membrane | a few thousand in total | building and detailed design |
| A shower room on the ground floor | less during construction than PLN 25,000–40,000 later | concept |
| Mechanical ventilation with heat recovery | PLN 30,000–80,000 for a house of 200 m² and up | concept and detailed design |
Indicative 2026 prices, from offers by contractors we work with, not a quote. The first three lines are the whole point of this part: they are decisions about where things sit, not about what things cost.
We design the utility room away from the bedroom wall: it costs nothing and is settled in the first week.
What this part does not show
- These are cohort studies. They show that something occurs together with something else, not that one causes the other. People who use a sauna four times a week may differ from those who never do in ways nobody measured.
- None of this is medical advice. A house is not a treatment and we are not doctors.
- The profile of our own houses is read from room schedules, so it says whether a sauna exists, not whether anyone uses it.
- Several criteria are assessed on eleven houses, because that is how many have a connection graph.
What this means when designing
A sauna only works if it is close. What counts in the studies is frequency, and frequency depends on the distance from the bedroom, not on the specification of the cabin.
The utility room belongs away from the bedroom wall. It costs nothing in the first week and cannot be fixed afterwards.
Sources. Sauna, the Kuopio cohort, 2,315 men, about 20 years of follow-up: Laukkanen et al., JAMA Internal Medicine 2015 and Laukkanen et al., Age and Ageing 2017. Hot bathing, the Japanese JPHC study, about 30 thousand people: Ukai et al., Heart 2020. Cooking: Chen et al., Public Health Nutrition 2012. UK Biobank: sleep regularity, 61 thousand people, Windred et al., Sleep 2024; light exposure, 89 thousand, Windred et al., PNAS 2024; stairs, 459 thousand, Song et al., Atherosclerosis 2023. Meta-analyses: strength training, 16 cohorts, Momma et al., British Journal of Sports Medicine 2022; steps, 15 cohorts, Paluch et al., Lancet Public Health 2022; greenery, 143 studies, Twohig-Bennett and Jones, Environmental Research 2018; relationships, 148 studies and 309 thousand people, Holt-Lunstad et al., PLoS Medicine 2010. Falls: Cochrane review, Gillespie et al., Cochrane 2012. Air and cognitive function, Harvard COGfx: Allen et al., Environmental Health Perspectives 2016. Bedroom air: Strøm-Tejsen et al., Indoor Air 2016. Light: Brown et al., PLOS Biology 2022. Noise: WHO, Guidelines for community noise, 1999 and WHO, Environmental noise guidelines, 2018. Housing and health: WHO, Housing and health guidelines, 2018. Radon: WHO, Handbook on indoor radon, 2009. Time use: NHAPS, Klepeis et al., 2001. Standards EN 17037 and EN 16798-1. House data: MOOMOO detached house plan study, final edition, October 2026, parts 13 and 14.
Licence. The figures and charts in this part are released under CC BY 4.0. They may be quoted, adapted and used commercially, crediting MOOMOO Architects as the source. Photographs and visualisations are not covered by the licence.
The whole study in one file
A hundred and thirty-five pages, twenty houses and apartments, fourteen parts and a hundred and eighteen drawings. Everything this series was built from, in full. The file is in Polish; the drawings and tables read without it, and an English edition is in preparation.
135pages 20houses 14parts 118drawings
Prefer to look first? The whole series is readable here, part by part, without signing up.
Compiled by: Łukasz Pastuszkaarchitect, co-founder, MOOMOO Architects